Search found 6 matches

by kempas
April 17th, 2012, 11:54 pm
Forum: Civil Construction
Topic: Need to verify Quotations for Painting work
Replies: 1
Views: 3143

Need to verify Quotations for Painting work

Hi, I need some experts or someone who recently experienced building their house to verify the below rates. These are revised rates after the recent budget. Sl.No. Particulars Unit Rate/Unit 1 Plastic Emulsion : Cleaning the surface,applying of Birla wall care putty -2coats, +1coat Asian Putty, 1 Co...
by kempas
April 17th, 2012, 11:47 pm
Forum: Civil Construction
Topic: Need to verify Quotations for Plumbing work
Replies: 0
Views: 1996

Need to verify Quotations for Plumbing work

Hi All, I am looking for some experts or people who recently undertook their house construction to verify the quotation below. can someone please help? Description Unit Rate/unit Supplying & Fixing of Astral /Ashirvad Flowguard SDR 11 Category CPVC pipes with necessary fittings. a. 3/4" (20mm) Rft 9...
by kempas
April 17th, 2012, 11:42 pm
Forum: Civil Construction
Topic: Need to verify Quotations for fabrication work
Replies: 1
Views: 2425

Need to verify Quotations for fabrication work

Hi, I am looking for some experts to verify the below quotations for MS fabrication work. I have chosen the simplest possible design for the railings and doors here. could someone please help? Particulars Nos unit Rate/unit Amount Outside Staircase/Balcony Grills 1 Sft 160.00 20800.00 Garage Door 1 ...
by kempas
February 6th, 2012, 8:02 am
Forum: Interiors
Topic: Home Security Alarm - Bosch Vs Honeywell?
Replies: 2
Views: 4145

Home Security Alarm - Bosch Vs Honeywell?

Hi, I have already gone through a detailed thread on Home security system in this website. Going through the multiple vendors listed there I couldn't find any vendor better than Eureka Forbes (atlease their sales team is good and responsive). I have tried registering (in other vendors' websites)/cal...
by kempas
February 2nd, 2012, 9:37 pm
Forum: General
Topic: Recommend good building contractor and architect
Replies: 16
Views: 15321

Re: Recommend good building contractor and architect

blrsiteseeker,
would you mind giving out details of the architect who was helpful to you.
Rgds,
by kempas
January 25th, 2012, 8:51 pm
Forum: General
Topic: site with 'A' Khata but non-approved layout Plan is it safe?
Replies: 14
Views: 16783

Re: site with 'A' Khata but non-approved layout Plan is it s

Please don't go for such sites ('A' Katha in Non-approved layout) unless the layout plan is clearly laid out and also approved by a competent authority, otherwise there is always chance of what Mr. Chandramouli has stated here.

Go to advanced search