Search found 89 matches

by Nagendra_81
September 18th, 2018, 2:39 pm
Forum: Civil Construction
Topic: Sand type for Footings and Columns
Replies: 1
Views: 2989

Sand type for Footings and Columns

Hi All,

Is it a good idea to go for River sand only for Footings and Columns.. and use M-sand for other areas of the building.
What is the general recommendation. Please suggest.

Thanks.
by Nagendra_81
September 18th, 2018, 1:26 pm
Forum: Civil Construction
Topic: UPVC vs WPC vs Sal /Madandi wood windows
Replies: 3
Views: 4873

Re: UPVC vs WPC vs Sal /Madandi wood windows

It is used in my apartment. But I dont have any contacts or much info about the finish.. I think any wholesale dealer should have that brand ..
by Nagendra_81
September 17th, 2018, 11:16 am
Forum: Civil Construction
Topic: UPVC vs WPC vs Sal /Madandi wood windows
Replies: 3
Views: 4873

Re: UPVC vs WPC vs Sal /Madandi wood windows

KOS UPVC is also good and costs much less. I think < 500 per sq feet.
by Nagendra_81
September 11th, 2018, 3:03 pm
Forum: Civil Construction
Topic: Concealed or hidden beams
Replies: 3
Views: 4758

Re: Concealed or hidden beams

thanks a lot Praveen .
by Nagendra_81
September 11th, 2018, 11:39 am
Forum: Civil Construction
Topic: Concealed or hidden beams
Replies: 3
Views: 4758

Concealed or hidden beams

Planning on doing a Parking+3 floor construction. Is it safe to conceal the beams, i.e align the beams along with the ceiling to a large extent .. atleast for the parking floor.. ? The idea is to have a relatively low height for the parking floor, so am trying to avoid the beams which would usually ...
by Nagendra_81
August 28th, 2018, 3:59 pm
Forum: Civil Construction
Topic: Elevator help
Replies: 11
Views: 13869

Re: Elevator help

How about Otis Gen2 CORE ? Looks like its more suitable for residential houses.
by Nagendra_81
August 19th, 2017, 12:34 pm
Forum: Civil Construction
Topic: Only Boundary Columns for 30*40 site
Replies: 8
Views: 9691

Re: Only Boundary Columns for 30*40 site

Ok. Thanks everyone.
by Nagendra_81
August 18th, 2017, 12:02 pm
Forum: Civil Construction
Topic: Only Boundary Columns for 30*40 site
Replies: 8
Views: 9691

Re: Only Boundary Columns for 30*40 site

That pic is very interesting. To optimize that design for my case, I could probably have that center pillar and its beams concealed, underneath the cellar parking floor. That way, I can still park as many cars as possible. But I guess I also need to consult a structural engineer or an Architect, if ...
by Nagendra_81
August 17th, 2017, 9:52 pm
Forum: Civil Construction
Topic: Only Boundary Columns for 30*40 site
Replies: 8
Views: 9691

Re: Only Boundary Columns for 30*40 site

Yes, that should help give some stability. But I recently saw 1 building with columns only in the boundary. So looks like it is possible. But I dont know how safe it would be.
by Nagendra_81
August 17th, 2017, 1:35 pm
Forum: Civil Construction
Topic: Only Boundary Columns for 30*40 site
Replies: 8
Views: 9691

Only Boundary Columns for 30*40 site

Hi All, Would it be possible to have columns only at the edges/boundaries of the plot, i.e without any columns inside the plot itself for a G+3 on 30*40 site. This would give a lot of flexibility in terms of placing the walls. Also since I plan on having a complete cellar parking, it gives a lot of ...

Go to advanced search